A ductless mini split system is a compact unit that consists of an outdoor compressor unit and one or more indoor air handlers.
Ducted mini split in attic.
This means one outdoor unit matched with one indoor unit.
Install two mitsubishi sez model ducted minisplits in the attic.
Each zone has multiple rooms all served by a single fan coil.
The attic at inverter s house is unconditioned.
An hvac contractor has taken a look at the house and has a recommendation inverter explains in this q a post.
All mini split concealed duct units feature a condensate removal pump that removes water resulting from the cooling of warm humid air.
For a single room cooling such as an attic application all you need is 1 1 mini split configuration.
One will cool the master bedroom the other will cool the two bedrooms where inverter s children sleep.
Pioneer ducted concealed mini split systems offer climate control for multiple rooms and areas utilizing a network of air ducts existing or field designed using a single set of equipment.
Concealed duct units typically come with a wall mounted control for adjusting temperature and output.
You will need to attach a drain pipe or pvc to the pump in order to drain the condensate.
Understanding manual j occupant loads.
Ducted mini split systems can be installed in ceilings attics closets or under the floor but as with any heating or cooling system proper load sizing and installation is key.
Integrating solar electric and solar thermal panels.
Ducted minisplits in my conditioned attic part 1 calculating the loads and sizing the system.